CO-DS1 (DS1 CO Trunk)
Issue 5 October 2002
911
555-233-119
1020
ABORT
The DS1 Interface circuit pack is out-of-service.
1. Look for DS1-BD errors in the Hardware Error Log. If present, refer to
DS1-BD (DS1 Trunk Circuit Pack) Maintenance documentation.
2. Retry the command.
1040
ABORT
The test was aborted because this port may be an access endpoint.
1. Verify that this port is an access endpoint by issuing the display port
command.
2. If the port has been administered as an access endpoint, this is a
normal abort.
2000
ABORT
Response to the test request was not received within the allowable time
period.
2012
ABORT
The test was aborted due to an internal system error.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
FAIL
The trunk cannot be seized for an outgoing call. This could cause in-line
failures to be reported against the trunk (no answer would report error type
257 with auxiliary data 57487 in the error log).
1. Verify that the Trunk Type field on the trunk administration screen form
matches the trunk type administered on far end switch.
2. Look for DS1-BD/UDS1-BD errors in Hardware Error Log. If present,
refer to the appropriate DS1-BD/UDS1-BD (DS1/UDS1 Trunk Circuit
Pack) Maintenance documentation.
3. Retry the test at 1-minute intervals for a maximum of 5 times.
Table 158.
TEST #314 DS1CO Dial Tone Seizure Test —
Continued
Error
Code
Test
Result
Description/ Recommendation