Maintenance Objects
555-233-119
654
Issue 5 October 2002
1018
ABORT
The test has been disabled via administration. The default for the
Test
field
on the Station screen is y. Determine why this field has been set to
n
for this
station. It may be due to application Test #48, which can disturb users or
terminal operations.
1. To enable the test for the station being tested, enter change station
extension and set the
Test
field to y.
2000
ABORT
Response to the test request was not received within the allowable time
period.
2100
ABORT
Could not allocate the necessary system resources to run this test. This could
be due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL
The reflective loop around test failed. This could cause noisy or unreliable
connections, or users calling this port may hear an echo. The problem can also
be off-board.
1. Since the test may be affected by a line seizure, repeat the test at
1-minute intervals for a maximum of 5 times.
2. Use test board PCSS short to run circuit pack tests to check the tone
generator circuit pack and the tone detector circuit pack.
3. Resolve any problems on the tone generator circuit pack or the tone
detector circuit pack.
4. If the tone generator and tone detector circuit packs are functioning
properly, a voice terminal is connected and wired properly and the test still
fails, replace the analog line circuit pack.
PASS
The port is able to provide an analog transmission path to the station
equipment. User-reported troubles on this port should be investigated by using
other port tests, by examining station wiring, or by examining the station.
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use list config
and resolve any problems.
2. If the board was found to be correctly inserted in step 1, use busyout
board.
3. Issue reset board.
4. Issue release busy board.
5. Issue test board long. This should re-establish the linkage between the
internal ID and the port. If this is not the case, check to ensure that there is
a valid board inserted.
Table 43. TEST #161 Looparound Test —
Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page