Maintenance Objects
1548
Issue 5 October 2002
Battery Feed Test (also called Port Diagnostic
Test) (#35)
The battery feed chip provides power to the telephone equipment, signaling,
rotary dial pulsing, transmission, and balance. This test checks the signaling and
switchhook capabilities of the battery feed chip by terminating the port, applying
battery and detecting the resulting current.
Table 434.
TEST #35 Battery Feed Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000
ABORT
System resources required to run this test are not available. The port
may be busy with a valid call. This result is also reported for the
system’s Music-On-Hold port when it is off-hook, which it usually is.
1. Enter display port UUCSSpp to determine the station’s
extension. Enter status station extension to determine the
service state of the port. If the port is in use, wait until the port is
idle.
2. Retry the command at 1-minute intervals a maximum of 5 times.
1004
ABORT
The port was seized by a valid call during the test. The test has been
aborted. Use the display port UUCSSpp command to determine the
station extension. Use the status station command to determine the
service state of the port. If the port is in use, wait until the port is idle.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1005
ABORT
The test was aborted due to a configuration problem. This test may
not be applicable, or it may be disruptive to terminal equipment other
than a voice terminal (for example, the modem pool member or
Music On Hold).
1018
ABORT
The test has been disabled via administration. The default for the
Test
field on the Station form is
y
.
1. Determine why this field has been set to
n
on this station (this
may be due to the ringing application test 48, which can be
customer or terminal disturbing).
2. To enable the test for the particular analog station being tested,
enter change station extension and set the
Test?
field on the
Station form to
y
.
Continued on next page