test customer-alarm
Issue 5 October 2002
543
555-233-119
Output
The following example shows the output from test customer-alarm 02a.
Field Definitions
Port
The port address (cabinet-carrier-slot)
Maintenance
Name
The maintenance name (always CUST-ALM)
Alt. Name
Not applicable
Test No.
The test number (always 115)
Result
Test result: Pass, Abort, or Fail
Error Code
Numeric code explaining why the release failed or aborted. See
the detailed list of the codes by test number for each MO.
test customer-alarm 02A
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
02A CUST-ALM 115 PASS