TBRI-TRK (TN2185 ISDN Trunk-Side BRI)
Issue 5 October 2002
1653
555-233-119
2074
ABORT
Bit and Block Error query failed.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, there may be a serious internal problem
with M/T-DIG (Maintenance/Test Digital Port). If this is the case, refer to
the M/T-DIG (Maintenance/Test Digital Port) Maintenance
documentation.
2075
ABORT
Internal System Error.
1. Follow the recommendations for ABORT code 2012.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2104
ABORT
Call dropped or could not be originated.
1. Make sure service is provisioned by the network.
2. Check the administration of the far-end test line extension on the trunk
group administration form.
3. Check the administration of the test call BCC (Bearer Capability Class)
on the trunk group administration form.
4. Try the test again.
2201
2202
2203
2204
2205
ABORT
Internal System Error.
1. Follow the recommendations for ABORT code 2012.
2206
ABORT
Could not allocate the necessary system resources to run this test.
1. Follow the recommendations for ABORT code 2100.
2208
ABORT
Internal System Error.
1. Follow the recommendations for ABORT code 2012.
2209
2210
ABORT
Could not allocate the necessary system resources to run this test.
1. Follow the recommendations for ABORT code 2100.
2211
ABORT
Internal System Error.
1. Follow the recommendations for ABORT code 2012.
2212
ABORT
Call terminated by unexpected disconnect.
1. Wait one minute and then try again.
2213
ABORT
The call has timed-out, perhaps because of a lack of system resources.
1. Follow the recommendations for ABORT code 2035.
Table 485.
TEST #258 ISDN TEST Call —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page