Maintenance Commands
555-233-119
540
Issue 5 October 2002
Field descriptions
test cdr-link
test cdr-link primary | secondary [short | long] [repeat number | clear]
[schedule]
Use test cdr-link to validate that a Call Detail Recording (CDR) link has been
administered and established. The test defaults to “short”.
Parameters
For more information see
“Common Input Parameters”
and
“Common Output
Fields”
at the beginning of this chapter.
Port
Port address (cabinet-carrier-slot-circuit): cabinet 1, carrier is A
(control carrier A in a simplex system) and either A or B (control
carriers A and B in a duplex system). The slot and circuit fields in
the port address for the CAP-MEM, and CARD-MEM maintenance
objects are always blank. The port address for maintenance object
FL-DATA is blank.
Maintenance
Name
The name of maintenance object being tested:
■
CARD-MEM for the memory card
■
CAP-MEM for memory card capacity
■
FL-DATA for the data consistency stored in memory cards
(duplicated switch)
Test No
The test being executed
Result
Test result: Pass, Fail, or Abort
Error Code
Numeric code explaining why the release failed or aborted. See
the detailed list of the codes by test number for each MO.
[primary | secondary]
A system may have up to two CDR links: a primary that is
normally used and a secondary that serves as a backup in case
the primary fails. This qualifier specifies which link to test.
Primary is the default.