ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon
Analog Line)
Issue 5 October 2002
671
555-233-119
7
13
14
15
(cont’d.)
FAIL
(cont’d.)
1. Disconnect the terminal equipment from the circuit pack at the
cross-connect and run the test again.
2. If the test fails again, replace the circuit pack and reconnect the terminal
equipment. If the test passes the second time, the test results were
affected by the terminal equipment connected to the port; in this case,
ignore the results of this test if all other tests pass or abort and the
station is operating properly. Failure of test 47 does not cause an alarm.
If there are failures of other tests, investigate those errors. User
reported troubles with this port should be investigated by using other
port tests, by examining station wiring, and by examining the station to
ensure that it is correctly translated as off-premises or on-premises.
NOTE:
If the loop around and conference circuit test fails for all ports on a
circuit pack, a -5 volt power problem is indicated.
PASS
The port is able to provide an analog transmission path to the station
equipment. User-reported troubles on this port should be investigated by
using other port tests, by examining station wiring, by examining the station,
and by ensuring that the terminal is correctly translated as off-premises or
on-premises.
NOTE:
This test always passes for TN742 Analog circuit packs prior to
Vintage 6.
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use list config,
and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, use busyout
board.
3. Issue reset board.
4. Issue release busy board.
5. Issue test board long. This should re-establish the linkage between
the internal ID and the port. If this is not the case, dispatch to check to
ensure that there is a valid board inserted.
Table 48. TEST #47 Loop Around and Conference Test —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page