S-SYN-PT (Speech Synthesis Port)
Issue 5 October 2002
1577
555-233-119
Notes:
a. An in-line failure of the on-board microprocessor/PSS handshake has
occurred. Refer to Test #168 for repair procedures.
b. This error type indicates that the circuit pack been removed or has been
insane for more than 11 minutes. To clear the error, reinsert or replace the
circuit pack.
c. A transient error that does not cause an alarm can occasionally occur
during a SPE, TDM BUS, or Tone Clock interchange. Test the port and
follow the instructions for conference Test (#7).
d. This error is not service-affecting and no action is required.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. By clearing error codes associated with the NPE Crosstalk
Test, for example, you may also clear errors generated from other tests in the
testing sequence.
For example, you may also clear errors generated from other tests in the testing
sequence.
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
1.
D = Destructive; ND = Nondestructive
Speech Synthesis PSS Handshake Test (#168)
X
X
ND
NPE Crosstalk Test (#6)
X
ND
Conference Circuit Test (#7)
X
ND
Speech Synthesis DTMF Receiver Test (#163)
X
ND
Speech Synthesis Memory Test (#166)
X
X
ND
Speech Synthesis DSP Tone Test (#165)
X
X
ND
Speech Synthesis SSD Inquiry Test (#167)
X
X
ND
Speech Synthesis DTMF Receiver Inquiry Test (#164)
X
X
ND
Speech Synthesis Parameter Update Test (#169)
X
X
ND