ADX8D-PT (AUDIX Digital Port)
Issue 5 October 2002
619
555-233-119
1001
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1002
ABORT
The system could not allocate time slots for the test. The system may be
under heavy traffic conditions, or may have time slots that are out-of-service
due to TDM-BUS errors.
1. If the system has no TDM-BUS errors, and is not handling heavy traffic,
retry the command at 1-minute intervals a maximum of 5 times.
1003
ABORT
The system could not allocate a tone receiver for the test. The system may be
oversized for the number of Tone Detectors present, or some Tone Detectors
may be out-of-service.
1. Resolve any “TTR-LEV” errors.
2. Resolve any “TONE-PT” errors.
3. If neither condition exists, retry the command at 1-minute intervals a
maximum of 5 times.
1004
ABORT
The port was put in use during the test. Use display port PCSSpp to
determine the voice port extension of the port. Use status station to
determine the service state of the port. If the service state indicates that the
port is in use, wait until the port is idle before retesting.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2000
ABORT
Response to the test was not received within the allowable time period.
2100
ABORT
Could not allocate the necessary system resources for this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Table 31. TEST #13 Voice and Control Channel Local Loop Test —
Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page