Maintenance Commands
555-233-119
482
Issue 5 October 2002
Emerg Trans
Settings for emergency transfer switches on the maintenance board for
each cabinet. Available options are: auto-on (“auto+” or “a+”), auto-off
(“auto-” or “a-”), “on”, “off”, and “n.a.”. The system defaults to “auto+” or
“auto-”. In this state, emergency transfer activate automatically if the
cabinet fails (“+”=emergency transfer is activate, “-” = emergency
transfer is inactive). “on” = emergency transfer automatically activates.
“off”=the cabinet cannot activate emergency transfers. Duplicated SPEs
systems = switch settings for both processors of the PPN (cabinet 1)
display. In this case, “auto+” is abbreviated “a+”, “auto-” is abbreviated
“a-”, and “off” is abbreviated “of”. “on” does not change. “n.a.” = the
emergency transfer switch setting is unavailable.
Mj
Number of major alarms associated with the cabinet. Asterisks are used
to fill fields when numbers exceed 99.
Mn
Number of minor alarms associated with the cabinet. Asterisks are used
to fill fields when numbers exceed 99.
Wn
Number of warnings associated with the cabinet. Asterisks are used to fill
fields when numbers exceed 99.
PNC
Port Network Connectivity (PNC) status for each port networks within a
cabinet. When multiple port networks exist, Carriers A, B, and C are
listed first and separated from Carriers D and E by a slash (for example,
up/up).
Time of Day
Current time of day acquired from the system.