UDS1-BD (UDS1 Interface Circuit Pack)
Issue 5 October 2002
1833
555-233-119
PASS
The RLB test executed successfully. The test pattern was transmitted and
received successfully over the connection from the UDS1 board to the
far-edge of the 120A1 CSU Module or the 401A T1 Sync Splitter.
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Ensure that the board translations are correct. Execute the add ds1
UUCSS command to administer the UDS1 interface if it is not already
administered.
2. If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If this is the case, the board
is shut down. Reseating the board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, then issue the
busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port.
Table 541.
TEST #1211 CSU Repeater Loopback Test —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page