Maintenance Objects
1484
Issue 5 October 2002
Hardware Error Log Entries and Test to Clear
Values
Notes:
a. The PMS Link has been busied out for system technician-demanded
maintenance via the busyout pms-link command. The link is torn down.
Enter the release pms-link command to restore the link.
Table 396.
PMS-LINK Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test pms sh r 1
18 (a)
0
busyout pms-link
WARNING
OFF
release pms-link
257 (b)
0-6,
99,
255
Link Retry Test
(#215)
MINOR/
WARNING
2
2.
Minor alarms on this MO may be downgraded to Warning alarms based on the value used in the
set options command.
OFF
test pms-link l
513 (c)
0-6,255
None
test pms-link
769 (d)
0-6,255
None
1025 (e)
4x
3
3.
Is any integer.
None
1281 (f)
1x
3
None
1537 (g)
Nx
3
None
1793 (h)
0-6,255
None
test pms-link
2049 (i)
0-6,255
None
2305 (j)
5x
3
None
release pms-link or
test pms-link
2561 (k)
0-6,255
None
test pms-link
2817 (l)
10x
3
20x
3
30x
3
None
3073 (m)
7x
3
None
3841 (n)
2x
3
None
Continued on next page