ANN-BD (Announcement Circuit Pack)
Issue 5 October 2002
699
555-233-119
!
WARNING:
Announcement circuit pack alarms are upgraded to MAJOR when the BASE
Tone Generator is set to 12 (France).
Notes:
a. Error Type 1
This error indicates the circuit pack totally stopped
functioning or it was physically removed from the system.
NOTE:
The alarm is logged about 11 minutes after the circuit pack has been
removed and/or SAKI Test (#53) fails.
2305
140AY Loop
Around Test (#210)
MINOR
ON
test board PCSS sh r 3
2561
Super Frame
Match Inquiry Test
(#211)
MINOR
ON
test board PCSS sh r 3
17676
In-line Error
2817 (
k
)
Announcement
Checksum Test
(#209)
MINOR
ON
test board PCSS sh r 3
17682
In-line Error
17699
(m)
In-line Error
3840(
m
)
Any
None
3999 (
n
)
Any
None
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Table 56. Announcement Circuit Pack Error Log Entries —
Continued
Error
Type
Aux
Data
Associated Test
Alarm Level
(See WARNING
message below)
On/Off
Board
Test to Clear Value
Continued on next page