VC-BD
Issue 5 October 2002
1885
555-233-119
Error Log Entries and Test to Clear Values
Notes:
a. The circuit pack stopped functioning or it was removed from the system.
This alarm is logged approximately 11 minutes after the circuit pack is
removed and/or the SAKI Sanity Test (#53) fails.
To resolve this error, insert a circuit pack in the same slot as the error
indicates, if the circuit pack is not already in the system. Or, if the circuit
pack is in the system and the red LED is on, then follow instructions for
Red alarms.
!
CAUTION:
If the TN788 Voice Conditioner Circuit Pack (VC-BD) is not Vintage 2
or later, it must be replaced.
b. This circuit pack is busied out by the busyout board PCSS command.
Table 564.
VC-BD Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the short test sequence first. If all tests pass, run the long test sequence. Refer to the appropriate
test description and follow the recommended procedures.
0
Any
Any
Any
test board PCSS sh r 1
1 (a)
Any
None
MIN
ON
18 (b)
0
busyout board PCSS
WNG
OFF
release board PCSS
257 (c)
Any
Control Channel Loop
Test (#52)
MIN
ON
test board PCSS r 20
513 (d)
4352 to
4357
769 (e)
4358
1025 (f)
4363
NPE Audit Test (#50)
1281 (g)
Any
SAKI Sanity Test (#53)
MAJ
ON
1293 to
1294 (h)
46088
to
46096
SAKI Sanity Test (#53)
MIN
ON
See note (g)
1538 (i)
46082
MIN
ON
Continued on next page