Maintenance Objects
555-233-119
614
Issue 5 October 2002
Error Log Entries and Test to Clear Values
Notes:
a. Error type 0 - Run the Short Test Sequence first. If all tests pass, run the
Long Test Sequence. Refer to the appropriate test description and follow
the recommended procedures.
b. Minor alarms on this MO may be downgraded to Warnings based on the
values in set options.
c. Error type 1 - The user may experience a noisy port or link. This is an
off-board problem that is detected by the port circuit. If this problem exists,
replace the circuit pack (see caution at the beginning of this section). Once
the problem is resolved, the alarm is retired after a predetermined time.
d. Error type 1 - At least 15 off-board problems have been detected with the
link to the voice port. When an error with the link is detected, an on-board
counter is incremented. Also see Note (
a
).
e. Error type 15 is an internal error that occurs when an audit request fails.
f. Error type 18 - The port is busied-out by command. Use release port
PCSSpp to release the port.
Error
Type
Aux
Data
Associated Test
Alarm Level
On/Off
Board
Test to Clear Value
0 (
a
)
0
Any
Any
Any
test port PCSSpp sh r 1
1 (
c
)
40987
None
WARNING
OFF
1 (
d
)
1 to
20
None
WARNING
OFF
15 (
e
)
Any
None
18 (
f
)
0
busyout port
PCSSpp
WARNING
OFF
release port PCSSpp
23 (
g
)
0
None
WARNING
OFF
130 (
h
)
None
WARNING
ON
test port PCSSpp sh
257 (
i
)
40971
None
513 (
j
)
Any
None
1537 (
k
)
40968
None
WARNING
OFF
1793
Voice & Ctrl. Local
Loop Test (#13)
MIN/WRN(
b
)
ON
test port PCSSpp l r 3
2049
NPE Crosstalk
Test (#9)
MIN/WRN(
b
)
ON
test port PCSSpp l r 3
2305 (
l
)
40967
None
3840 (
m
)
40965
None
3840 (
n
)
41029
None