TEST #0 Dial Tone Test
Error
Code
Test
Result
Description/ Recommendation
ABORT
Could not allocate system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000
ABORT
System resources required to run this test are not available. The port may
be busy with a valid call. Use the command display port PCSSpp to
determine the trunk group/member number of the port. Use the status
trunk command to determine the service state of the port. If the service
state indicates that the port is in use, the port is unavailable for certain
tests. Wait until the port is idle before retesting.
1. If the port status is idle, retry the command at 1-minute intervals a
maximum of 5 times.
1001
ABORT
System resources required to run this test were not available. This could be
due to a failure to seize the port.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1002
ABORT
The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors. Refer to TDM-BUS (TDM Bus) Maintenance
documentation to diagnose any active TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at 1-minute intervals a maximum of 5 times.
1004
ABORT
The port was seized by a user for a valid call. Use the display port
PCSSpp command to determine the trunk group/member number of the
port. Use the status trunk command to determine the service state of the
port. If the service state indicates that the port is in use, the port is
unavailable for certain tests. W wait until the port is idle before retesting.
1. If the port status is idle, retry the command at 1-minute intervals for a
maximum of 5 times.
1005
ABORT
Trunk has been administered as incoming-only; dial tone can only be
obtained on outgoing trunks. This is a normal condition.
1018
ABORT
Test has been disabled via administration.
1. Verify that the
Maintenance Tests
field on the Trunk Group Form
is set to n. To enable the test, use change trunk-group x where “x”
equals the number of the trunk group to be tested, and set the
Maintenance Tests
field to y.
2000
ABORT
Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page