Maintenance Objects
555-233-119
896
Issue 5 October 2002
Tone Detector Audit/Update Test (#43)
A sanity audit is performed on the CLSFY-PT (Call Classifier Port).
Table 153.
Tone Detector Audit/Update Test (#43)
Error
Code
Test
Result
Description/ Recommendation
none
ABORT
The system was not able to allocate all the resources needed for this test.
1. Wait 1 minute, and repeat the command a maximum of 5 times.
2000
ABORT
Response to the test request was not received within the allowable time
period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL
Hardware audit failed.
1. Run the short test sequence with test port PCSSpp sh r 1.
2. If the problem persists, the system is still operating properly but system
capacity will be reduced. In order to restore system performance to
normal, replace the CLSFY-BD (Call Classifier circuit pack) containing
the defective CLSFY-PT (Call Classifier Port).
PASS
The (CLSFY-PT) Call Classifier Port has passed the sanity inquiry.
Continued on next page