PPP-PT (Control LAN Packet/Port)
Issue 5 October 2002
1503
555-233-119
TCP/IP Ping Test (#1281)
This non-destructive test fails if the endpoint fails to respond. Use this test to
check the circuitry in the data path for a peer-to-peer IP layer connection.
2100
ABORT
Could not allocate the necessary system resources to run test.
1. Retry the command at 1-minute intervals, up to 5 times.
2. Escalate if the problem persists.
FAIL
CLAN circuit pack detected test failure.
1. If the problem persists, reset the circuit pack (busyout board UUCSS,
reset board UUCSS, and release board UUCSS).
2. If the problem persists, replace the circuit pack.
PASS
Port circuitry functioning properly.
Table 406.
TEST #1281 TCP/IP Ping Test
Error
Code
Test
Result
Description/ Recommendation
1, 2, 7,
11
ABORT
Internal error
1. Retry the command at 1-minute intervals up to 3 times
2. Escalate if the problem persists.
1005
ABORT
Test configuration is incorrect.
1. Verity PPP link is in-service (status clan-port UUCSSpp or status link
n).
2. Repeat the test.
3. Escalate if the problem persists.
1124
ABORT
ppp link is not enabled.
1. Verify that the ppp link is enabled (status port UUCSSpp, status link
n, or display data-module).
2. If the link is not enabled, enable the link (change data-module).
3. Repeat the test.
4. Escalate if the problem persists.
Continued on next page
Table 405.
TEST #1275 SCOTCH Synchronous Looparound Test —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page