DT-LN-BD (Data Line Circuit Pack)
Issue 5 October 2002
1145
555-233-119
DT-LN-BD (Data Line Circuit Pack)
Refer to XXX-BD (Common Port Circuit Pack) Maintenance documentation for
circuit pack level errors. See also DAT-LINE (Data Line Circuit Port) Maintenance
documentation for related line information.
0
NO
BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is inserted, an incorrect
board is inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the add
ds1 UUCSS command to administer the DS1 interface if it is not already
administered.
2. If board was already administered correctly, check the error log to
determine if the board is hyperactive. If this is the case, the board is shut
down. Reseating the board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, issue the
busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port.
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to Run
1
1.
Where P is the port network number (1 for PPN); C is the carrier designation (for
example, A, B, or C); and SS is the address of the slot in the carrier where the circuit
pack is located (for example, 01, 02, etc.).
Full Name of MO
DT-LN-BD
MIN
test board PCSS sh
Data Line Circuit Pack
DT-LN-BD
WRN
test board PCSS sh
Data Line Circuit Pack
Table 244.
TEST #1227 ICSU Status LEDs Test — Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page