Maintenance for CSI systems
555-233-119
34
Issue 5 October 2002
7. Find the DID-TRK MO in the Maintenance Object chapter of the
appropriate maintenance book.
8. In the first table, look up the command to run in the MAJOR row of the
table.
In our example, Step
4
indicated that a DID trunk in slot 10, carrier C has a
MAJOR alarm.
9. Type test port 01C1008 long and press
Enter
.
In our example, 01C1008 is the address of the alarmed port (see
Screen 2
on page 33
and
Screen 3 on page 33
).
10. While the port test is running, look up the Error Type in the appropriate
Error Log Entries table.
In our example the Error type is 1537.
11. Since the Test to Clear Value (
test port 01C1008 sh r 1) is similar to the initial
test you ran in Step
9
, wait for the results of the port test.
When the port test finishes, a Test Results screen appears (
Screen 4 on
page 35
).
MO Name (in
Alarm Log)
Alarm Level
Initial Command to Run
1
1.
UU is the universal cabinet number (1 for PPN, 2 - 44 for EPNs), C is the carrier designation (A, B,
C, D, or E), SS is the number of the slot in which the circuit pack resides (01 to 21), and pp is the
two digit port number (01, 02, ...).
Full Name of MO
DID-TRK
MAJOR
2
2.
A MAJOR alarm on a truk indicates that alarms on these trunks are downgraded by the set options
command and that at least 75% of the trunks in this trunk group are alarmed.
test port UUCSSpp long
DID Trunk
DID-TRK
MINOR
test port UUCSSpp long
DID Trunk
DID-TRK
WARNING
test port UUCSSpp
DID Trunk
Table 2.
DID Trunk Error Log entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
1537
Port Diagnostic
(#35)
MAJ/MIN/
WRN
OFF
test port UUCSSpp sh r 1
3840 (k)
40965
None
Continued on next page