555-233-119
1214
Issue 5 October 2002
c. Error Type 259 — a log only error indicating that the target board failed to
download. To resolve the error, use the command test firmware
download. The Aux Data specifies the error. See
Table 274
for more
details.
5
Invalid TN code on the change firmware download screen does not
match TN code of image on the source board. Verify screen, make
sure the correct image is being used.
6
Invalid suffix on the change firmware download screen does not
match suffix of image on the source board. Verify screen, make sure
the correct image is being used.
7
Source board not present, verify entry on the change firmware
download screen, and translations.
8
Incorrect source board, verify that the source board is the correct TN
code.
9
PPP ports not available, use another source board or reschedule the
download for off hours.
10
DL Setup message to source failed. Retry download and if download
still fails escalate.
Table 274.
Error Type 259 Aux Data
Aux
Data
Description of Failure
1
Target board not present / not responding, check board location,
translations and retry.
2
Incorrect target board for download schedule, verify board location,
and schedule.
3
Target failed to go into DL Mode, retry
4
Target received bad file header
5
Bad image checksum on image on source board, get new image retry.
Continued on next page
Table 273.
Error Type 258 Aux Data
— Continued
Aux
Data
Description of Failure
Continued on next page