555-233-119
954
Issue 5 October 2002
Error Log Entries and Test to Clear Values
Notes:
a. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
Table 171.
Data Channel Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
(a)
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test data-module <ext> sh r 1
1
Any
Local Loop Back Test
(#111)
MINOR
ON
test data-module <ext> sh r 3
18
0
busyout data-module
<ext>
WARNING
OFF
release data-module <ext>
130
None
WARNING
ON
test data-module <ext> sh
257
Any
Remote Maintenance
Loop Around Test
(#109)
MINOR
ON
test data-module <ext> sh r 5
513
Any
Crosstalk Test (#110)
MINOR
ON
test data-module <ext> sh r 3
769
Any
Dual Port RAM Test
(#108)
MINOR
ON
test data-module <ext> l r 3