Maintenance Objects
1768
Issue 5 October 2002
Notes:
a. Error Type 1 — indicates that the circuit pack has totally stopped
functioning or is not fully administered. The alarm is logged about 15
minutes after the circuit pack has been removed or 11-minutes after the
SAKI Test (#53) fails.
To be fully administered, a UDS1 circuit pack must meet all three of the
following conditions:
1. Have an entry in the circuit plan using the change circuit pack
command
2. Be administered using the add ds1 UUCSS command
3. Be physically inserted into the correct slot
3330(w)
46083
MIN/WRN
3
ON
3585 to
3601 (x)
Any
Misframe Alarm Inquiry
Test (#145)
MIN/WRN
3
OFF
test board UUCSS r 6
3840(y)
Any
None
3841(z)
4358
3842(aa)
46097
3843(ab)
46081
3900(ac)
Any
CPE Loopback Jack
Test (#1212)
3901(ad)
Any
Far CSU Loopback Test
(#1213)
3902(ae)
Any
One-Way Span Test
(#1214)
3999(af)
Any
None
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2.
If ports are assigned to the circuit pack, then a minor alarm is raised. If no ports are assigned to the
circuit pack, then a warning alarm is raised. The alarm is raised after the circuit pack has been
missing for a period of 15 minutes. Warning alarms are also raised against any ports administered
on the circuit pack.
3.
Minor alarms on this MO may be downgraded to warning alarms based on values set in the set
options command.
4.
Major alarms on this MO may be downgraded to minor or warning alarms based on values set in
the set options command.
Table 524.
DS1 Interface Circuit Pack Maintenance Error Log Entries —
Continued
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
Continued on next page