DIOD-TRK (DIOD Trunk)
Issue 5 October 2002
1063
555-233-119
1004
ABORT
The port was seized by a valid call during the test. The test has been
aborted. Use the display port PCSSpp command to determine the trunk
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the service state indicates that the
port is in use, then the port is unavailable for certain tests. You must wait
until the port is idle before retesting.
2000
ABORT
Response to the test request was not received within the allowable time
period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Any
FAIL
The NPE of the tested port was found to be transmitting in error. This
causes noisy and unreliable connections.
1. Replace the circuit pack.
PASS
The port is correctly using its allocated time slots. User-reported troubles on
this port should be investigated by using other port tests and by examining
trunk or external wiring.
Table 217.
TEST #6 NPE Crosstalk Test — Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page