CLSFY-PT (Call Classifier Port)
Issue 5 October 2002
895
555-233-119
101-122
FAIL
Forward or Backward MFC signals were not correctly generated or
detected. This impacts reception of incoming MFC calls.
1. Run the short test sequence with test port PCSSpp sh r 1.
2. If the problem persists, the system is still operating properly but system
capacity will be reduced. In order to restore system performance to
normal, replace the Call Classifier circuit pack containing the defective
CLSFY-PT (Call Classifier Port).
PASS
Tone Detection Verification is successful. The Call Classifier Port
(CLSFY-PT) is able to detect/generate all necessary tones.
Table 152.
TEST #42 Tone Detection Verification Test —
Continued
Error
Code
Test
Result
Description/ Recommendation