RDIG-STA (Remote Digital Station)
Issue 5 October 2002
1567
555-233-119
1392
ABORT
This port is currently a TTI port and the test will not execute on it.
1. Verify that the port is a TTI port using either the display port
command (the display shows that the port is a TTI port) or the list
config command (the display shows a
t
for the port).
2. If either list config or display port indicate that the port is not a
TTI port, escalate the problem. If both commands indicate that the
port is a TTI port, the abort is correct, and no action is necessary.
2000
ABORT
Response to the test was not received in the allowable time period.
FAIL
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS
Station Audits passed. This Digital Port circuit pack is functioning
properly.
1. If complaints persist, investigate by using other port tests, and by
examining the station, wiring, and connections.
Table 442.
TEST #17 Station (Digital) Audits Test —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page