Maintenance Objects
1914
Issue 5 October 2002
Hardware Error Log Entries and Test to Clear
Values
Notes:
a. This error indicates the circuit pack totally stopped functioning or it was
physically removed from the system. This error type is not applicable to
ANN-BD, DETR-BD, S-SYN-BD, M/T-BD, or CLSFY-BD.
NOTE:
The alarm is logged approximately 11 minutes after the circuit pack
has been removed and/or SAKI Sanity Test (#53) fails.
Common Port Circuit Pack Maintenance Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test board PCSS sh r 1
1(a)
0
Circuit pack removed
or SAKI Sanity Test
(#53)
MINOR
ON
18(b)
0
busyout board PCSS
WARNING
OFF
release board PCSS
23(c)
0
None
WARNING
OFF
125 (d)
None
MINOR
ON
257
65535
Control Channel
Test (#52)
MINOR
ON
test board PCSS sh r 20
257 (e)
Any
None
267 (d)
0
None
WARNING
ON
513 (f)
Any
None
MINOR
ON
test board PCSS sh
769 (g)
4358
None
1025 (h)
4363
NPE Audit Test
(#50)
test board PCSS l r 20
1281 (i)
Ringing Application
Test (#51)
MINOR
ON
test board PCSS r 2
1538 (j)
Any
None
WARNING/
MINOR
ON
1793 (k)
Neon Test (#220)
MINOR
ON
test board PCSS r 2
3840 (l)
Any
None
3999 (m)
Any
None