Maintenance Objects
555-233-119
658
Issue 5 October 2002
Notes:
a. Error type 0: Run the Short Test Sequence first. If all tests pass, run the
Long Test Sequence. Refer to the appropriate test description and follow
the recommended procedures.
b. Error type 1: These are in-line errors and can only be resolved over time.
■
40960
—
indicates that too many simultaneous incoming ringing
attempts were made on this board. Only four ports on a board may
be ringing simultaneously. A fifth incoming call will cause an inline
error from the board.
■
40975
—
indicates that the terminal equipment was on-hook when
ring-tip was detected during ringing. This usually indicates a failure
in the terminal equipment or the type of terminal has a low ringer
impedance. Call the terminal equipment and verify that the terminal
rings. If the terminal doesn’t ring, replace it. Otherwise, use test
port PCSSpp, and follow the procedure for Test #48.
■
40977
—
indicates that no terminal equipment was connected when
ringing was attempted. Use test port PCSSpp to run the Short Test,
and follow the procedure for the results of Test #48.
c. Error type 15 is a software audit error that does not indicate any hardware
malfunction. Run Short Test Sequence and investigate errors (if any).
d. Error type 130 indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
e. Error type 257: Test #48 applies momentary ringing voltage to terminal
equipment and monitors resulting current flow to determine whether the
equipment is connected to the port. Test #48 may cause some terminal
equipment to ring briefly during daily maintenance. If this disturbs the user
or the phone equipment, to disable Test #48 use change station
extension
and set the
Tests
field to n. On some software releases, this also disables
Tests #6, 7, 161, 35, and 47.
f. Error type 769: Test #47 may cause a false alarm when the port is
connected to off-premises equipment, some non-voice terminal equipment,
and some loop equipment. If this causes a false alarm, enter n in the Tests
field of change station to disable the test.
g. Error types 1281 and 1793: refer to “XXX-BD (Common Port Circuit Pack)”
Maintenance documentation.