test inads-link
Issue 5 October 2002
559
555-233-119
Field descriptions
The following example shows the output for test hardware-group system with
the background option.
test inads-link
Use test inads-link to attempt a call over the inads port on the maintenance
board to verify the INADS alarm notification process. In the default settings, the
system tests the link to the first OSS telephone number. If there is an alarm
pending to be reported or the call is in progress or up, then the test aborts. If the
alarm origination to the OSS telephone number to be tested is disabled, then the
test generates an informative error and the test continues. The test waits 2
minutes before dialing the call to allow the remote maintenance technician to
logoff, thus freeing the line. A local SAT user entering test inads-link does not
need to log off for the system to place the call, but the two-minute delay still exists.
Port
Port address (cabinet-carrier-slot-circuit)
Maintenance
Name
The name of maintenance object
Alt. Name
Alternate way to identify maintenance objects.
If the Object isThe field contains
stationextension
trunkxxx/yyy (where xxx = trunk group number
and yyy = member number)
private CO lineP/xxx (where xxx = private CO line group
number)
Test No.
The test being executed
Result
Test result: No Board, Extra Bd, Disabled, or Skipped
Error Code
Numeric code explaining why the release failed or aborted. See
the detailed list of the codes by test number for each MO.
test hardware-group system
Command started in background mode