3.9 Environmental ConditionsLicense Requirements
This system is carrier class designed and complies with Considered equivalent to ATIS-0600010.01.2008 Class 2, Harsh – Protected Environment.
This system will properly work within Class 2 environments for equipment placed inside a space protected from direct outside weather and
environmental stresses by a closure and where the operating climate is between:
-40°C (-40°F) and 65°C (149°F)
5 and 85 RH% Relative Humidity
“These locations usually have either (a) active means of cooling using fans and/or heat exchangers, or (b) design features (cooling fins or airflow
pattern) within the closure or the equipment to effectively dissipate heat from active equipment.
Although these facilities do not have a preset specific temperature range as a target, their physical design features (e.g., cooling fins) and devices
(e.g., fans, heat exchangers) greatly aid heat dissipation and help moderate the thermal environment surrounding the electronic equipment.
The temperature conditions above are the expected extremes provided for equipment design purposes. Normal operating temperature and
humidity range experienced by the equipment in the closure is expected to be narrower. The operating temperature minimum of -40°C represents
a scenario where a cold start is required after an emergency, such as a power outage caused by an ice storm or downed electrical power lines.”
(GR-3108-CORE).
3.10 Electromagnetic Compatibility
This system is carrier class designed and suitable to work over extreme EM conditions. As such, it complies with the relevant recommendations for
this type of installation, as listed in the ETSI EN 300 386 recommendation.
3.11 System Parts
The organization of the OLT system can be seen in the figure below, Figure 3-3 and Table 3-11.
Figure 3-3: OLT system Front View (1U chassis)
Module
Name
Status
OLT Ref.769401 single board
OLT Ref.769401
Ready
Fan Module
OLT Ref.769401
Ready
Air Filter
OLT Ref.769401
Ready
Table 3-11: OLT Equipment Module Features
Summary of Contents for OLT 769401
Page 1: ...GPON OLT 8xPON 8xGbE 2x10GbE EN Ref 769401 User Manual w w w t e l e v e s c o m ...
Page 2: ......
Page 9: ...EN 9 ...
Page 11: ...EN 11 ...
Page 139: ...EN 139 Figure 6 9 SFP Module detailed information Figure 6 10 GPON Interfaces Status ...
Page 149: ...EN 149 Figure 6 20 DHCP counters ...
Page 473: ...EN 473 ...
Page 474: ......
Page 475: ......
Page 476: ......
Page 477: ...EN 477 ...
Page 478: ...Descripción del producto 478 ...
Page 479: ...EN 479 ...
Page 480: ...Descripción del producto 480 ...
Page 481: ...EN 481 ...
Page 482: ...Descripción del producto 482 ...