1. Blower motor
2. Blower motor resister
3. Blower fan switch
4. Ignition switch
5. Lighting switch
TO ECM
(Idl up signal)
HEATER AND VENTILATION
1A-5
DIAGNOSIS
DIAGNOSIS TABLE
Trouble
Possible Cause
Remedy
Heater blower won’t work
even when its switch is
ON.
Blower fuse blown
Blower motor resistor faulty
Blower fan switch faulty
Blower motor faulty
Wiring or grounding faulty
Check for short to ground and replace
fuse.
Check resistor.
Check blower fan switch.
Replace motor.
Repair as necessary.
Incorrect temperature
output.
Control cables broken or binding
Temperature control lever faulty
Control cable clamp position is faulty
Air damper broken
Air ducts clogged
Heater core leaking or clogged
Heater hoses leaking or clogged
Thermostat faulty
Check cables.
Check control lever.
Check and adjustment.
Repair damper.
Repair air ducts.
Replace core.
Replace hoses.
Check thermostat.
When mode control lever
is changed, air outlet port
is not changed or lever
position disagree with air
outlet port.
Control cables broken or binding
Air damper broken
Air ducts clogged
Air damper broken
Air ducts leaking or clogged
Check cable.
Check control lever.
Check and adjustment.
Repair damper.
Repair air ducts.
WIRING CIRCUIT
Summary of Contents for RA410
Page 262: ...ENGINE MECHANICAL 6A4 3...
Page 388: ...ENGINE AND EMISSION CONTROL SYSTEM 6E1 23 Blank...
Page 392: ...ENGINE AND EMISSION CONTROL SYSTEM 6E1 27 Fig for Step 3 2 3 1...
Page 399: ...6E1 34 ENGINE AND EMISSION CONTROL SYSTEM Fig for Step 2...
Page 552: ...AUTOMATIC TRANSMISSION 7B 25...
Page 553: ...7B 26 AUTOMATIC TRANSMISSION...
Page 663: ...BODY SERVICE 9 21 BUMPERS Front bumper Rear bumper...
Page 761: ...Prepared by Overseas Service Department 1st Ed May 1998 Printed in Japan Printing May 1999 610...