INSTALLATION
Reverse removal procedure giving specified tension to drive belt
referring to SECTION 6B.
Tightening Torque
(a): 22 N
·m (2.2 kg-m, 16.0 lb-ft)
(b): 50 N
·m (5.0 kg-m, 36.5 lb-ft)
(c): 7 N
·m (0.7 kg-m, 5.0 lb-ft)
(c)
(a)
(b)
6H-20
CHARGING SYSTEM
SPECIFICATIONS
Rated voltage
12 V
Permissible ambient
– 30 to 90 °C
Nominal output
65 A (at 13.5 V)
temperature
(– 22 to 194 °F)
Permissible max. speed
18,000 rpm
Polarity
Negative ground
No-load speed
1,180 rpm
Rotation
Clockwise viewed
Setting voltage
14.2 to 14.8 V
Rotation
from pulley side
Summary of Contents for RA410
Page 262: ...ENGINE MECHANICAL 6A4 3...
Page 388: ...ENGINE AND EMISSION CONTROL SYSTEM 6E1 23 Blank...
Page 392: ...ENGINE AND EMISSION CONTROL SYSTEM 6E1 27 Fig for Step 3 2 3 1...
Page 399: ...6E1 34 ENGINE AND EMISSION CONTROL SYSTEM Fig for Step 2...
Page 552: ...AUTOMATIC TRANSMISSION 7B 25...
Page 553: ...7B 26 AUTOMATIC TRANSMISSION...
Page 663: ...BODY SERVICE 9 21 BUMPERS Front bumper Rear bumper...
Page 761: ...Prepared by Overseas Service Department 1st Ed May 1998 Printed in Japan Printing May 1999 610...