Higher Voltage
If voltage is higher than standard value, check ground of brush.
If brush ground is correct, replace IC regulator.
Lower Voltage
If voltage is lower than standard value, proceed to the following
check.
2) Ground F terminal and start engine, then measure voltage at B
terminal as shown in left figure.
Voltage is higher than standard value
It is considered that generator itself is good but IC regulator
has been damaged, replace IC regulator.
Voltage is lower than standard value
Generator itself has problem and check the generator.
LOAD CHECK
1) Run engine at 2,000 rpm and turn on head light and heater mo-
tor.
2) Measure current and if it is less than 20 A repair or replace gen-
erator.
OVERCHARGED BATTERY
1) To determine battery condition, refer to Battery section.
2) If obvious overcharge condition exists as evidenced by exces-
sive spewing of electrolyte, proceed to disassembly section of
generator service and check field windings for grounds and
shorts. If problem exists, replace rotor.
3) With engine running at 5,000 rpm, measure voltage.
4) If measured voltage is out of standard value, check brush
ground or IC regulator.
–30
–22
0
32
25
77
HEATSINK TEMPERATURE
REGULA
TED VOL
T
AGE (V)
16.0
15.0
14.0
13.0
14.2
13.3
14.8
14.8
15.3
14.2
135( C)
275( F)
6H-10
CHARGING SYSTEM
Summary of Contents for RA410
Page 262: ...ENGINE MECHANICAL 6A4 3...
Page 388: ...ENGINE AND EMISSION CONTROL SYSTEM 6E1 23 Blank...
Page 392: ...ENGINE AND EMISSION CONTROL SYSTEM 6E1 27 Fig for Step 3 2 3 1...
Page 399: ...6E1 34 ENGINE AND EMISSION CONTROL SYSTEM Fig for Step 2...
Page 552: ...AUTOMATIC TRANSMISSION 7B 25...
Page 553: ...7B 26 AUTOMATIC TRANSMISSION...
Page 663: ...BODY SERVICE 9 21 BUMPERS Front bumper Rear bumper...
Page 761: ...Prepared by Overseas Service Department 1st Ed May 1998 Printed in Japan Printing May 1999 610...