Appendix
B-56
7SA6 Manual
C53000-G1176-C156-2
10314 Uph-e<(<) Pickup L3 (Uph-e<(<) PU L3)
Voltage Protection OUT
*
ON
OFF
LED
BO
73
114 2
GI
10315 Uph-e< TimeOut (Uph-e< TimeOut)
Voltage Protection OUT
*
*
LED
BO
10316 Uph-e<< TimeOut (Uph-e<< TimeOut)
Voltage Protection OUT
*
*
LED
BO
10317 Uph-e<(<) TRIP command (Uph-e<(<)
TRIP)
Voltage Protection OUT
*
ON
LED
BO
73
117 2
GI
10325 Uph-ph< Pickup (Uph-ph< Pickup)
Voltage Protection OUT
*
ON
OFF
LED
BO
73
125 2
GI
10326 Uph-ph<< Pickup (Uph-ph<< Pickup)
Voltage Protection OUT
*
ON
OFF
LED
BO
73
126 2
GI
10327 Uphph<(<) Pickup L1-L2 (Uphph<(<)PU
L12)
Voltage Protection OUT
*
ON
OFF
LED
BO
73
127 2
GI
10328 Uphph<(<) Pickup L2-L3 (Uphph<(<)PU
L23)
Voltage Protection OUT
*
ON
OFF
LED
BO
73
128 2
GI
10329 Uphph<(<) Pickup L3-L1 (Uphph<(<)PU
L31)
Voltage Protection OUT
*
ON
OFF
LED
BO
73
129 2
GI
10330 Uphph< TimeOut (Uphph< TimeOut)
Voltage Protection OUT
*
*
LED
BO
10331 Uphph<< TimeOut (Uphph<< TimeOut)
Voltage Protection OUT
*
*
LED
BO
10332 Uphph<(<) TRIP command (Uphph<(<)
TRIP)
Voltage Protection OUT
*
ON
LED
BO
73
132 2
GI
>Back Light on (>Light on)
Device
SP
ON
OFF
*
BI
>Cabinet door open (>Door open)
Process Data
SP
on
off
*
LED BI
BO
CB
101 1
1
GI
>CB waiting for Spring charged (>CB wait) Process Data
SP
on
off
*
LED BI
BO
CB
101 2
1
GI
>Error Control Voltage (>ErrCntrlU)
Process Data
SP
on
off
*
LED BI
BO
CB
240 182 1
GI
>Error Meter (>Err Meter)
Process Data
SP
on
off
*
LED BI
BO
CB
240 184 1
GI
>Error Motor Voltage (>Err Mot U)
Process Data
SP
on
off
*
LED BI
BO
CB
240 181 1
GI
>SF6-Loss (>SF6-Loss)
Process Data
SP
on
off
*
LED BI
BO
CB
240 183 1
GI
>Transformer Danger (>Tx Danger)
Process Data
SP
on
off
*
LED BI
BO
CB
240 186 1
GI
>Transformer Temperature (>Tx Temp.)
Process Data
SP
on
off
*
LED BI
BO
CB
240 185 1
GI
Breaker (Breaker)
Control Device
CF_D12
on
off
*
BO
240 160 1
GI
Breaker (Breaker)
Control Device
DP
on
off
*
BI
CB
240 160 1
GI
Breaker OPENED (Brk OPENED)
Device
IntSP
*
*
LED
BO
CB1-TEST trip/close Phases L123 (CB1tst
123)
Testing
-
*
*
CB1-TEST trip/close - Only L1 (CB1tst L1) Testing
-
*
*
CB1-TEST trip/close - Only L2 (CB1tst L2) Testing
-
*
*
F.No.
Description
Function
Type of
Informa-
tion
Log-Buffers
Configurable in Matrix
IEC 60870-5-103
E
v
e
n
t
Log
O
n
/O
ff
T
rip
(F
au
lt)
L
o
g
On
/Of
f
G
ro
u
n
d
Fa
ul
t
Log
O
n
/O
ff
Mar
k
ed
in
Osc
ill.
Reco
rd
LE
D
Bin
a
ry
In
p
u
t
Fu
nc
ti
o
n
K
e
y
Bin
a
ry
Ou
tp
u
t
C
h
a
tte
r
B
loc
k
in
g
Ty
pe
In
fo
rm
at
io
n
-No
Da
ta
Un
it
(A
SDU)
G
e
ne
ra
l
In
te
rro
ga
ti
o
n
Summary of Contents for siprotec 7SA6
Page 2: ...Siemens Aktiengesellschaft Book No C53000 G1176 C156 2 ...
Page 18: ...xviii 7SA6 Manual C53000 G1176 C156 2 ...
Page 32: ...Introduction 1 14 7SA6 Manual C53000 G1176 C156 2 ...
Page 82: ...Hardware and Connections 2 50 7SA6 Manual C53000 G1176 C156 2 ...
Page 119: ...SIPROTEC 4 Devices 4 25 7SA6 Manual C53000 G1176 C156 2 Figure 4 20 CFC Logic example ...
Page 190: ...Configuration 5 62 7SA6 Manual C53000 G1176 C156 2 ...
Page 652: ...Installation and Commissioning 8 78 7SA6 Manual C53000 G1176 C156 2 ...
Page 724: ...Technical Data 10 56 7SA6 Manual C53000 G1176 C156 ...
Page 800: ...Appendix A 76 7SA6 Manual C53000 G1176 C156 2 ...
Page 866: ...Appendix B 66 7SA6 Manual C53000 G1176 C156 2 ...