Appendix
B-27
7SA6 Manual
C53000-G1176-C156-2
402
>Q MIN/MAX Buffer Reset (>Q MiMa
Reset)
Min/Max Mea-
surement Setup
SP
ON
*
LED BI
BO
403
>Idmd MIN/MAX Buffer Reset (>Idmd
MiMaReset)
Min/Max Mea-
surement Setup
SP
ON
*
LED BI
BO
404
>Pdmd MIN/MAX Buffer Reset (>Pdmd
MiMaReset)
Min/Max Mea-
surement Setup
SP
ON
*
LED BI
BO
405
>Qdmd MIN/MAX Buffer Reset (>Qdmd
MiMaReset)
Min/Max Mea-
surement Setup
SP
ON
*
LED BI
BO
406
>Sdmd MIN/MAX Buffer Reset (>Sdmd
MiMaReset)
Min/Max Mea-
surement Setup
SP
ON
*
LED BI
BO
407
>Frq. MIN/MAX Buffer Reset (>Frq MiMa
Reset)
Min/Max Mea-
surement Setup
SP
ON
*
LED BI
BO
408
>Power Factor MIN/MAX Buffer Reset
(>PF MiMaReset)
Min/Max Mea-
surement Setup
SP
ON
*
LED BI
BO
410
>CB1 aux. 3p Closed (for AR, CB-Test)
(>CB1 3p Closed)
Power System
Data 2
SP
*
*
LED BI
BO
150 80
1
GI
411
>CB1 aux. 3p Open (for AR, CB-Test)
(>CB1 3p Open)
Power System
Data 2
SP
*
*
LED BI
BO
150 81
1
GI
501
Relay PICKUP (Relay PICKUP)
Power System
Data 2
OUT
*
*
M
LED
BO
128 84
2
GI
503
Relay PICKUP Phase L1 (Relay PIKKUP
L1)
Power System
Data 2
OUT
*
*
M
LED
BO
128 64
2
GI
504
Relay PICKUP Phase L2 (Relay PIKKUP
L2)
Power System
Data 2
OUT
*
*
M
LED
BO
128 65
2
GI
505
Relay PICKUP Phase L3 (Relay PIKKUP
L3)
Power System
Data 2
OUT
*
*
M
LED
BO
128 66
2
GI
506
Relay PICKUP Earth (Relay PICKUP E)
Power System
Data 2
OUT
*
*
M
LED
BO
128 67
2
GI
507
Relay TRIP command Phase L1 (Relay
TRIP L1)
Power System
Data 2
OUT
*
*
M
LED
BO
128 69
2
508
Relay TRIP command Phase L2 (Relay
TRIP L2)
Power System
Data 2
OUT
*
*
M
LED
BO
128 70
2
509
Relay TRIP command Phase L3 (Relay
TRIP L3)
Power System
Data 2
OUT
*
*
M
LED
BO
128 71
2
510
Relay GENERAL CLOSE command
(Relay CLOSE)
Power System
Data 2
OUT
*
*
*
LED
BO
511
Relay GENERAL TRIP command (Relay
TRIP)
Power System
Data 2
OUT
*
OFF
M
LED
BO
128 68
2
512
Relay TRIP command - Only Phase L1
(Relay TRIP 1pL1)
Power System
Data 2
OUT
*
*
LED
BO
513
Relay TRIP command - Only Phase L2
(Relay TRIP 1pL2)
Power System
Data 2
OUT
*
*
LED
BO
514
Relay TRIP command - Only Phase L3
(Relay TRIP 1pL3)
Power System
Data 2
OUT
*
*
LED
BO
515
Relay TRIP command Phases L123
(Relay TRIP 3ph.)
Power System
Data 2
OUT
*
*
LED
BO
530
LOCKOUT is active (LOCKOUT)
Power System
Data 2
IntSP
ON
OFF
ON
OFF
LED
BO
150 170 1
GI
F.No.
Description
Function
Type of
Informa-
tion
Log-Buffers
Configurable in Matrix
IEC 60870-5-103
E
v
en
t
L
o
g
On
/O
ff
T
rip
(F
au
lt)
L
o
g
On
/Of
f
G
roun
d
F
a
u
lt
Lo
g
O
n
/O
ff
M
a
rk
e
d
in
Osc
ill.
Reco
rd
LED
B
ina
ry
In
pu
t
Fun
ct
io
n
K
e
y
B
ina
ry
O
u
tp
ut
C
h
at
te
r
B
lo
c
k
in
g
Ty
pe
In
fo
rm
a
tio
n
-N
o
D
a
ta
Un
it
(A
SDU)
G
e
ne
ra
l
In
te
rr
oga
ti
o
n
Summary of Contents for siprotec 7SA6
Page 2: ...Siemens Aktiengesellschaft Book No C53000 G1176 C156 2 ...
Page 18: ...xviii 7SA6 Manual C53000 G1176 C156 2 ...
Page 32: ...Introduction 1 14 7SA6 Manual C53000 G1176 C156 2 ...
Page 82: ...Hardware and Connections 2 50 7SA6 Manual C53000 G1176 C156 2 ...
Page 119: ...SIPROTEC 4 Devices 4 25 7SA6 Manual C53000 G1176 C156 2 Figure 4 20 CFC Logic example ...
Page 190: ...Configuration 5 62 7SA6 Manual C53000 G1176 C156 2 ...
Page 652: ...Installation and Commissioning 8 78 7SA6 Manual C53000 G1176 C156 2 ...
Page 724: ...Technical Data 10 56 7SA6 Manual C53000 G1176 C156 ...
Page 800: ...Appendix A 76 7SA6 Manual C53000 G1176 C156 2 ...
Page 866: ...Appendix B 66 7SA6 Manual C53000 G1176 C156 2 ...