Remote Commands
R&S
®
Cable Rider ZPH
503
User Manual 1321.0950.02 ─ 07
Example:
MMEM:MOVE '\Public\Screen
Shots\Screen0002.png','\Public\Screen
Shots\Screen0001.png'
Renames Screen0002.png to Screen0001.png
MMEM:MOVE '\Public\Screen
Shots\Screen0001.png','\Public\Test\Pic1.png'
Moves file Screen0006.png to the 'Test' folder and renames the
file Pic1.png.
Usage:
Setting only
MMEMory:RDIRectory
<DirectoryName>
This command deletes the indicated directory. The directory name includes the path
and may also include the drive name. The path name complies with DOS conventions.
This command is an event and therefore has no *RST value and no query.
Parameters:
<DirectoryName>
String containing the path of the directory to delete.
Example:
MMEM:RDIR '\Public\Screen Shots\
Deletes the directory 'Screen Shots'.
Usage:
Setting only
MMEMory:STORe:STATe
<1>, <TargetFile>
This command stores the current device settings in a *set file.
This command is an event and therefore has no *RST value and no query.
Parameters:
<1>
<TargetFile>
Example:
MMEM:STOR:STAT 1,'DATASET001.SET'
Saves the current device settings in the file DATASET001.SET.
Usage:
Setting only
SYSTem:SET:LOCK
<arg0>
This command adds write-protection to a dataset.
Parameters:
<arg0>
String containing the path and name of the dataset.
Example:
SYST:SET:LOCK 'Dataset001.set'
Protects the file Dataset001.set from overwriting.
Remote Control - Commands