Remote Commands
R&S
®
Cable Rider ZPH
380
User Manual 1321.0950.02 ─ 07
Suffix:
<1...2>
.
1...2
Parameters:
<Return values>
ElLength
Numerical value in mm
Example:
CALC:TRAC:CABL:LENG:RES?
Queries the measurement result of the electrical cable length.
Usage:
Query only
CALCulate<1...2>:TRACe:CABLe:LENGth[:STATe]
<State>
This command turns the electrical length format on and off.
The numeric suffix at CALCulate is irrelevant for this command.
Suffix:
<1...2>
.
1...2
Parameters:
<State>
ON | OFF
*RST:
OFF
Example:
CALC:TRAC:CABL:LENG ON
Activates the electrical cable length.
Reading Out Measurement Results
The following commands query various measurement results.
List of commands
CALCulate<1...2>:MARKer<1...6>:FUNCtion:DTF:PEAK:RESult?
.......................................380
CALCulate<1...2>:TRACe:CABLe:LOSS:RESult?
............................................................. 381
CALCulate<1...2>:TRACe:VSWR:AVG:RESult?
................................................................ 381
CALCulate<1...2>:TRACe:LIMit:VSWR:FAIL?
................................................................... 381
CALCulate<1...2>:TRACe:VSWR:MAX:RESult?
................................................................382
CALCulate<1...2>:MARKer<1...6>:FUNCtion:DTF:PEAK:RESult?
This command queries the DTF peak result on the marker position.
The numeric suffix at CALCulate is irrelevant for this command.
The numeric suffix at MARKer define the marker position.
Suffix:
<1...2>
.
1...2
<1...6>
1...6
Example:
CALC:MARK1:FUNC:DTF:PEAK:RES?
Return the DTF peak value at marker 1 postion.