Remote Commands
R&S
®
Cable Rider ZPH
346
User Manual 1321.0950.02 ─ 07
DISPlay<1...2>:LOSS:REFerence
<RefLevel>
This command defines the reference level for the cable loss measurement format.
The numeric suffix at DISPlay is irrelevant for this command.
Suffix:
<1...2>
.
1...2
Parameters:
<RefLevel>
Numeric value in the range from -100 dB to 100 dB.
*RST:
0 dB
Default unit: dB
Example:
DISP:LOSS:REF 10
Defines a reference level of 10 dB.
DISPlay<1...2>:LOSS:REFerence:POSition
<RefPosition>
This command defines the position of the reference value in the diagram for the cable
loss measurement format.
Each step shifts the reference position one grid line up or down.
The numeric suffix at DISPlay is irrelevant for this command.
Suffix:
<1...2>
.
1...2
Parameters:
<RefPosition>
Numeric value in the range from 0 to 10.
*RST:
10
Example:
DISP:LOSS:REF:POS 5
Moves the reference to the fifth grid line from the bottom.
DISPlay<1...2>:LOSS:Y:SCALe
<DisplayRange>
This command defines the display range of the vertical axis for the cable loss mea-
surement format.
The numeric suffix at DISPlay is irrelevant for this command.
Suffix:
<1...2>
.
1...2
Parameters:
<DisplayRange>
Numeric value in the range from 1 dB to 100 dB.
*RST:
100 dB
Default unit: dB
Example:
DISP:LOSS:Y:SCAL 20
Defines a display range of 20 dB
Remote Control - Commands