![Rohde & Schwarz 1321.1211.02 User Manual Download Page 498](http://html1.mh-extra.com/html/rohde-and-schwarz/1321-1211-02/1321-1211-02_user-manual_1477772498.webp)
Remote Commands
R&S
®
Cable Rider ZPH
491
User Manual 1321.0950.02 ─ 07
Suffix:
<1...2>
.
1...2
Parameters:
<Power>>
<numeric value>
Default unit: PCT
Example:
CALC:MARK:FUNC:DDEM:MPOW??
Query carrier power.
Usage:
Query only
[SENSe:]DDEMod
<DemodType>
This command selects the demodulation scheme of the signal you are measuring.
The numeric suffix at CALCulate is irrelevant for this command.
Parameters:
<DemodType>
ASK | FSK
ASK
Selects ASK modulation.
FSK
Selects FSK modulation.
Example:
DDEM ASK
Select measurement.
[SENSe:]DDEMod:FSK:OFFSet?
This command queries the measured frequency deviation of an FSK signal.
Prerequisites for this command: Select FSK demodulation
[SENSe:]DDEMod
on page 491.
The numeric suffix at CALCulate is irrelevant for this command.
Parameters:
<Frequency>>
<numeric value>
Default unit: Hz
Example:
DDEM:FSK:OFFS?
Query frequency deviation.
Usage:
Query only
TRACe<1...2>[:DATA]?
[<arg0>]
This command queries the trace data of the current measurement.
It also transfers data from a file to a particular trace.
With the command
FORMat[:DATA]
on page 354, you can set the data format.
Remote Control - Commands