Example:
CALC:DTF:CAB:PRES '5088-HLFR.CBLMOD'
Selects the cable model from the file 5088-HLFR.CBLMOD
Selecting the Measurement Mode
The following commands select the measurement mode.
List of commands
MEASurement<1...2>:MODE
.......................................................................................... 378
MEASurement<1...2>:MODE
<MeasMode>
This command selects the measurement mode.
The numeric suffix at MEASurement is irrelevant for this command.
Suffix:
<1...2>
.
1...2
Parameters:
<MeasMode>
DTFault | REFLection | LOSS
DTFault
Selects the distance-to-fault measurement.
REFLection
Selects the reflection measurement (S11).
LOSS
Selects the cable loss measurement.
*RST:
REFLection
Example:
MEAS:MODE LOSS
Activates cable loss measurement.
Selecting the Measurement Format
The following commands select the measurement format in CAT mode.
List of commands
CALCulate<1...2>:TRACe:VSWR:MAX[:STATe]
.................................................................378
MEASurement<1...2>:FORMat
........................................................................................ 379
CALCulate<1...2>:TRACe:CABLe:LENGth:RESult?
...........................................................379
CALCulate<1...2>:TRACe:CABLe:LENGth[:STATe]
........................................................... 380
CALCulate<1...2>:TRACe:VSWR:MAX[:STATe]
<State>
This command turns the display of the maximum and average VSWR on and off.
Use
CALCulate<1...2>:TRACe:VSWR:AVG:RESult?
on page 381 and
CALCulate<1...2>:TRACe:VSWR:MAX:RESult?
on page 382 to query the corre-
sponding results.
The numeric suffix at CALCulate is irrelevant for this command.