Remote Commands
R&S
®
Cable Rider ZPH
438
User Manual 1321.0950.02 ─ 07
Before you can use this command, you have to select the power measurement with
CALCulate<1...2>:MARKer<1...6>:FUNCtion:POWer:SELect
on page 435
and
CALCulate<1...2>:MARKer<1...6>:FUNCtion:POWer[:STATe]
on page 436.
This command is a query and therefore has no *RST value.
The numeric suffix at CALculate and MARKer are irrelevant for this command.
Parameters:
<arg0>
MCACpower | ACPower | CPOWer | OBANdwidth | OBWidth |
TDMA
MCACpower | ACPower
Returns the results for ACLR measurements.
The number of return values depends on the number of TX and
adjacent channel. The order of return values is:
power of the transmission channel.
power of the lower adjacent channel.
power of the upper adjacent channel.
power of the lower alternate channel 1.
power of the upper alternate channel 2.
etc.
The unit of the return values depends on the scaling of the verti-
cal axis:
logarithmic scaling returns the power in the currently selected
unit (see
UNIT<1...2>:POWer
on page 397).
linear scaling returns the power in W.
CPOwer
Returns the results for channel power measurements.
The return value is the power of the channel. The unit depends
on the scaling of the vertical axis:
logarithmic scaling returns the power in the currently selected
unit (see
UNIT<1...2>:POWer
on page 397).
linear scaling returns the power in W.
OBANdwidth | OBWidth
Returns the results for measurements of the occupied band-
width.
The return value is the occupied bandwidth in Hz.
TDMA
Returns the results for TDMA power measurements.
The return value is the power of the signal. The unit depends on
the scaling of the vertical axis:
logarithmic scaling returns the power in the currently selected
unit (see
UNIT<1...2>:POWer
on page 397).
linear scaling returns the power in W.