Remote Commands
R&S
®
Cable Rider ZPH
405
User Manual 1321.0950.02 ─ 07
Parameters:
<GateTrigger>
ON | OFF
*RST:
OFF
Example:
SWE:EGAT ON
Activates the gated trigger setting mode.
[SENSe:]SWEep:EGATe:HOLDoff
<GateTriggerHoldOff>
This command defines the length of the gate delay.
Parameters:
<GateTriggerHoldOff>Range:
0 s to 100 s
*RST:
0 s
Default unit: s
Example:
SWE:EGAT:HOLD 2.5
Sets a gate delay of 2.5 seconds.
[SENSe:]SWEep:EGATe:LENGth
<GateTriggerLength>
This command defines the gate length.
Parameters:
<GateTriggerLength> Range:
10 µs to 100 s
*RST:
400 µs
Default unit: s
Example:
SWE:EGAT:LENG 2.5
Sets a gate length of 2.5 seconds.
[SENSe:]SWEep:EGATe:TIME
<GateTriggerLength>
This command defines the sweep time for the gated trigger.
Parameters:
<GateTriggerLength> *RST:
400 µs
Default unit: s
Example:
SWE:GATE:TIME 4ms
Sets a sweep time of 4 ms for the gated trigger.
TRIGger[:SEQuence]:LEVel:VIDeo
<VideoTrigLevel>
This command defines the level of the video trigger.
Video trigger is available for time domain measurements (span
=
0).
Parameters:
<VideoTrigLevel>
Range:
0 PCT to 100 PCT
*RST:
50 PCT