Remote Commands
R&S
®
Cable Rider ZPH
366
User Manual 1321.0950.02 ─ 07
With span > 0, you can define a hold time at the marker position with
CALCulate<1...2>:MARKer<1...6>:FUNCtion:DEModulation:HOLD
on page 366.
In zero span, the demodulation is on permanently.
The numeric suffix at CALCulate is irrelevant for this command. The numeric suffix at
MARKer selects the marker.
Suffix:
<1...2>
.
1...2
<1...6>
1...6
Parameters:
<State>
ON | OFF
*RST:
OFF
Example:
CALC:MARK3:FUNC:DEM ON
Switches on the demodulation for marker 3.
CALCulate<1...2>:MARKer<1...6>:FUNCtion:DEModulation:HOLD
<HoldTime>
This command defines the hold time at the marker position for the demodulation with
span > 0.
The numeric suffix at CALCulate is irrelevant for this command. The numeric suffix at
MARKer selects the marker.
Parameters:
<HoldTime>
Range:
100 ms to 500 s
*RST:
0.5 (DEModulation is set to OFF)
Default unit: s
Example:
CALC:MARK:FUNC:DEM:HOLD 3s
Sets a hold time of 3 seconds.
CALCulate<1...2>:MARKer<1...6>:FUNCtion:DEModulation:SELect
<DemodType>
This command selects the type of demodulation type for the audio demodulator.
The numeric suffix at CALCulate is irrelevant for this command. The numeric suffix at
MARKer selects the marker.
Parameters:
<DemodType>
AM | FM
*RST:
AM
Example:
CALC:MARK:FUNC:DEM:SEL FM
Selects FM demodulation.
CALCulate<1...2>:MARKer<1...6>:FUNCtion:LEVel:ONCE
This command adjusts the reference level to the measured signal power.
Remote Control - Commands