Remote Commands
R&S
®
Cable Rider ZPH
481
User Manual 1321.0950.02 ─ 07
The numeric suffix at CALCulate is irrelevant for this command. The numeric suffix at
MARKer selects the marker.
Parameters:
<FrequencyOrTime> Indicates the coordinate on the horizontal axis.
The unit in spectrum analyzer mode depends on the measure-
ment, e.g. Hz for measurements in the frequency domain and
seconds for measurements in the time domain.
Range:
Maximum span.
Default unit: GHz
Example:
CALC:MARK2:X 10.7MHz
Positions marker 2 to frequency 10.7 MHz.
CALCulate<1...2>:MARKer<1...6>:Y?
This command queries the absolute vertical position of a marker.
If necessary, the corresponding marker is activated first.
To get a valid result, you have to perform a complete sweep with synchronization to the
sweep end between activating the delta marker and reading out the result. This is only
possible in single sweep mode.
The unit of the return value depends on
UNIT<1...2>:POWer
.
The numeric suffix at CALCulate is irrelevant for this command. The numeric suffix at
MARKer selects the marker.
Parameters:
<MarkerPosition>
Numeric value of the marker position.
Example:
INIT:CONF OFF
CALC:MARK2 ON
Turns on single sweep mode and marker 2.
INIT;*WAI
Starts a sweep and waits for the end.
CALC:MARK2:Y?
Queries the position of marker 2.
Usage:
Query only
CALCulate<1...2>:DELTamarker<1...6>[:STATe]
<State>
This command turns delta markers on and off.
If you set the suffix at DELTamarker to 1, or use no suffix, the R&S Cable Rider ZPH
interprets this as delta marker 2 because the first marker has to be a normal marker. If
more than one normal marker (2 to 6) is already active, the command turns these
markers into delta markers. If no delta marker is active yet, the command activates the
delta marker and positions it on the trace maximum.
The numeric suffix at CALCulate is irrelevant for this command. The numeric suffix at
DELTamarker selects the deltamarker.
Remote Control - Commands