Remote Commands
R&S
®
Cable Rider ZPH
433
User Manual 1321.0950.02 ─ 07
Example:
CALC:LIM1:UPP:THR -10DBM
Defines a threshold of -10 dBm.
14.6.3.9
Configuring and Using Measurement Functions
The R&S Cable Rider ZPH provides measurement functions that allow you to perform
advanced measurements and can also be controlled remotely.
●
Configuring Channel Tables
..................................................................................433
●
Power Measurements
........................................................................................... 435
●
Measuring the Channel Power
..............................................................................439
●
Measuring the Occupied Bandwidth
..................................................................... 440
●
TDMA Measurements
........................................................................................... 442
●
Measuring the Adjacent Channel Leakage Ratio
..................................................442
●
Measuring the Harmonic Distortion
.......................................................................453
●
Measuring the AM Modulation Depth
....................................................................456
●
Measuring the Spectrum Emission Mask
..............................................................456
●
Using an Isotropic Antenna
...................................................................................458
Configuring Channel Tables
The following commands configure the channel tables.
List of commands
[SENSe:]CHANnel<1...3>
............................................................................................... 433
[SENSe:]CHANnel:TABLe:SELect<1...4>
......................................................................... 433
[SENSe:]CHANnel:TABLe:SELect:DOWNlink
....................................................................434
[SENSe:]CHANnel:TABLe:SELect:UPLink
........................................................................ 434
[SENSe:]CHANnel:TABLe:SET
........................................................................................435
[SENSe:]CHANnel<1...3>
<ChannelNumber>
This command selects the channel to be analyzed.
You have to set the frequency mode with
[SENSe:]FREQuency:INPut:
MODE<1..3>
on page 389 to channel first.
The numeric suffix at CHANnel is irrelevant for this command.
Parameters:
<ChannelNumber>
Numeric value that selects the number of the channel to be ana-
lyzed.
*RST:
Depends on the channel table.
Example:
See
[SENSe:]CHANnel:TABLe:SELect<1...4>
on page 433.
[SENSe:]CHANnel:TABLe:SELect<1...4>
<ChannelTable>
This command selects a channel table configured for the link direction you have
selected with
[SENSe:]CHANnel:TABLe:SET
on page 435.
Remote Control - Commands