Remote Commands
R&S
®
Cable Rider ZPH
439
User Manual 1321.0950.02 ─ 07
Example:
POW:BAND 90PCT
Defines the occupied bandwidth (90%).
INIT:CONT OFF
INIT;*WAI
CALC:MARK:FUNC:POW:RES? OBW
Turns on single sweep mode, performs a measurement and
queries the results.
Usage:
Query only
Measuring the Channel Power
The following commands configure channel power measurements. To perform the
actual measurement, use the commands described in section
Chapter 14.6.3.5, "Per-
forming and Triggering Measurements"
,
on page 402.
List of commands
CALCulate<1...2>:MARKer<1...6>:FUNCtion:CPOWer:BANDwidth
.....................................439
CALCulate<1...2>:MARKer<1...6>:FUNCtion:CPOWer:MODE
............................................439
CALCulate<1...2>:MARKer<1...6>:FUNCtion:CPOWer:UNIT
..............................................440
CALCulate<1...2>:MARKer<1...6>:FUNCtion:POWer:RESult:PHZ
...................................... 440
CALCulate<1...2>:MARKer<1...6>:FUNCtion:CPOWer:BANDwidth
<ChannelBW>
This command defines the channel bandwidth for channel power measurements.
The numeric suffix at CALculate and MARKer are irrelevant for this command.
Parameters:
<ChannelBW>
*RST:
3.84 MHz
Default unit: GHz
Example:
CALC:MARK:FUNC:CPOW:BAND 4 MHZ
Sets the channel bandwidth to 4 MHz.
CALCulate<1...2>:MARKer<1...6>:FUNCtion:CPOWer:MODE
<DisplayMode>
This command selects the display mode for channel power measurements.
The numeric suffix at CALculate and MARKer are irrelevant for this command.
Parameters:
<DisplayMode>
CLR | MAX
CLR
Displays the currently measured value (Clear / Write).
MAX
Displays the highest measured value (Max Hold).
*RST:
CLR
Example:
CALC:MARK:FUNC:CPOW:MODE CLR
Selects clear/write power display mode.
Remote Control - Commands