Remote Commands
R&S
®
Cable Rider ZPH
488
User Manual 1321.0950.02 ─ 07
CALCulate<1...2>:MARKer:FUNCtion:DDEMod:CARRier[:RESult]?
This command queries the carrier power of the measured signal.
The numeric suffix at CALCulate is not irrelevant for this command.
Suffix:
<1...2>
.
1...2
Return values:
<Power>
<numeric value>
Default unit: dBm
Example:
CALC:MARK:FUNC:DDEM:CARR?
Query carrier power
Usage:
Query only
CALCulate<1...2>:MARKer:FUNCtion:DDEMod:CFDRift[:RESult]?
This command queries the carrier frequency drift of the measured signal.
Prerequisites for this command: Select FSK demodulation
[SENSe:]DDEMod
on page 491.
The numeric suffix at CALCulate is not irrelevant for this command.
Suffix:
<1...2>
.
1...2
Parameters:
<Frequency>
<numeric value>
Default unit: Hz/symbol
Example:
CALC:MARK:FUNC:DDEM:CFDR?
Query carrier frequency drift.
Usage:
Query only
CALCulate<1...2>:MARKer:FUNCtion:DDEMod:CFERror[:RESult]?
This command queries the carrier frequency error of the measured signal.
The numeric suffix at CALCulate is irrelevant for this command.
Suffix:
<1...2>
.
1...2
Parameters:
<Frequency>
<numeric value>
Default unit: Hz
Example:
CALC:MARK:FUNC:DDEM:CFER?
Query carrier frequency error.
Usage:
Query only