Cable and Antenna Test Mode
R&S
®
Cable Rider ZPH
150
User Manual 1321.0950.02 ─ 07
7.2.2.4
Selecting a Signal Standard for CAT Measurements (except DTF)
When you perform the reflection, cable loss, smith chart or phase measurement, the
R&S Cable Rider ZPH provides several configurations for measurements on a particu-
lar signal standard. When you select one of these standards, the R&S Cable Rider
ZPH loads the corresponding parameters like center frequency or span.
1. Press the [FREQ/DIST] key.
2. Select the "Signal Standard" softkey.
The R&S Cable Rider ZPH opens a submenu to select the signal standard.
3. Select either the "Select Uplink" or "Select Downlink" menu items.
The R&S Cable Rider ZPH opens the file manager to select the signal standard.
4. Select the standard you require.
The R&S Cable Rider ZPH load the settings of the standard you selected.
7.2.3
Configuring the Vertical Axis
The [SCALE] or [SCALE/AMPT] key contains menu on settings related to the level dis-
play.
7.2.3.1
Setting the Reference Value
The reference value defines the amplitude of the reference line. The R&S Cable Rider
ZPH indicates the position of the reference value with a white triangle at the vertical
axis.
When you change the reference value, the R&S Cable Rider ZPH adjusts the labels of
the vertical axis. Changing the reference value results a change in the vertical position
of the trace. It does not change the position of the reference line.
Configuring Cable and Antenna Tests