Remote Commands
R&S
®
Cable Rider ZPH
458
User Manual 1321.0950.02 ─ 07
AUTO
Turns on the Spectrum mode.
*RST:
AUTO
Example:
SWE:MODE ESP
Starts the SEM measurement.
Using an Isotropic Antenna
This chapter describes all commands available to set up measurements with an iso-
tropic antenna.
You can use an isotropic antenna with all measurement modes that are described
above.
List of commands
INPut:ANTenna:MEASure
............................................................................................... 458
INPut:ANTenna:STATe
....................................................................................................458
[SENSe:]CORRection:TRANsducer<1...2>:ISOTropic[:STATe]
............................................458
INPut:ANTenna:MEASure
<Direction>
This command selects the direction that the isotropic antenna measures.
Parameters:
<Direction>
AUTO | X | Y | Z
AUTO
Automatically selects the direction.
X | Y | Z
Measures the corresponding direction only.
*RST:
AUTO
Example:
INP:ANT:MEAS X
Measures in x-direction.
INPut:ANTenna:STATe
<State>
This command turns the use of an isotropic antenna on and off.
Parameters:
<State>
ON | OFF
*RST:
OFF
Example:
INP:ANT:STAT ON
Activates the isotropic antenna.
[SENSe:]CORRection:TRANsducer<1...2>:ISOTropic[:STATe]
<State>
This command queries if the currently selected transducer is an isotropic antenna.
Remote Control - Commands