Remote Commands
R&S
®
Cable Rider ZPH
486
User Manual 1321.0950.02 ─ 07
Parameters:
<FrequencyDev>
Range:
1 kHz to 200 kHz
Default unit: Hz
Example:
CALC:FSK:DEV:REF 1 KHZ
Set frequency deviation as 1 kHz.
[SENSe:]DDEMod:BURSt[:STATe]
<State>
This command turns burst processing on and off.
Parameters:
<State>
ON | OFF | 1 | 0
ON | 1
Turn on burst processing..
OFF | 0
Turn off burst processing..
Example:
DDEM:BURS ON
Turn on burst processing.
[SENSe:]DDEMod:FILTer:ALPHa
<Alpha>
This command defines the roll-off factor of the measurement filter (alpha or BT value).
Parameters:
<Alpha>
Range:
0 to 1
*RST:
1
Example:
DDEM:FILT:ALPH 0.35
Define roll-off factor.
[SENSe:]DDEMod:FILTer:NAME
<FilterName>
This command selects the measurement filter.
If you want to use no filter (unfiltered measurements), see
[SENSe:]DDEMod:
FILTer[:STATe]
on page 487.
Parameters:
<FilterName>
RRC | RC | GAUS
RRC
Selects a root raised cosine filter.
RC
Select a raised cosine filter.
GAUS
Select a Gaussian filter.
Example:
DDEM:FILT:NAME RRC
Select RRC filter.
Remote Control - Commands